"Engine not found" in AutoCAD or Revit
Symptom: a TX command stops with "The Tractrix engine (tractrix-engine) was not found" and a list of searched paths.
With the local engine, the add-in looks for tractrix-engine in: the path set in TXSETTINGS; the TRACTRIX_ENGINE environment variable; %ProgramData%\Tractrix\engine\; the add-in's engine folder; and PATH.
- Reinstall the add-in: the installer places the bundled engine in the add-in's
engine folder.
- If antivirus software quarantined
tractrix-engine.exe, restore it and add an exception.
- If you installed the engine with pip, set its full path in TXSETTINGS or in
TRACTRIX_ENGINE.
- Or switch TXSETTINGS to the cloud engine.
Steering exceedance explained
Symptom: an issue of kind steering_limit, with a value above the limit.
To follow your line, the nose wheel would have to turn further than the aircraft's maximum steering angle. The engine computes the angle from how quickly the heading changes along the path, δ = arctan(L dθ/ds), and marks the worst point. It usually means the curve is too tight for that aircraft, or the line has a kink.
- Check the line for a sharp vertex or a short zig-zag from digitising; replace corners with arcs of a realistic radius.
- Compare with the aircraft's minimum turning radius from Turning radii and 180° turn.
- Check
steer_source in the library: if a default limit (60° or 65°) was used, look up the manufacturer's value and enter it as an override.
- For pushback, the limit is the towing limit, not the aircraft's steering limit.